ANOVA results for the main cutting force (Fz) S/N ratio in Inconel 625.
Source | Degrees of freedom (DoF) | Sequential sum of squares (SS) | Mean sum of squares (MS) | F-test | P-coefficient (%) |
---|---|---|---|---|---|
Feed rate | 1 | 39.388 | 39.388 | 11.51 | 0.398 |
Cutting speed | 2 | 6.631 | 3.316 | 0.97 | 0.067 |
Cutting tool | 2 | 11.702 | 5.851 | 1.71 | 0.118 |
Residual error | 12 | 41.063 | 3.422 | 0.415 | |
Total | 17 | 98.784 |